Global Ozone Monitoring Experiment - 2 (GOME-2)
GOME-2 |
Global Ozone Monitoring Experiment - 2 |
Satellites |
MetOp 1 to 3 |
Status |
Operational - Utilised in the period 2006 to ~ 2020 |
Mission |
Ozone profile and total-column or gross profile of other species. Tracked species: BrO, ClO, H2O, HCHO, NO, NO2, NO3, O2, O3, O4, OClO, SO2 and aerosol |
Instrument type |
UV/VIS grating spectrometer, four bands, 4096 channels, with 200 polarisation channels |
Scanning technique |
Cross-track: 24 steps of 40 km or 80 km ssp, swath 960 or 1920 km - Along-track: one 40-km line every 6 s |
Coverage/cycle |
Global coverage every 3 days with high resolution or 1.5 days with low resolution. Daylight only |
Resolution (s.s.p.) |
40 x 40 km2 associated to 960 km swath or 40 x 80 km2 associated to 1920 km swath |
Resources |
Mass: 73 kg - Power: 42 W - Data rate: 400 kbps |
Spectral range |
Number of channels |
Spectral resolution |
SNR at specified input radiance |
240 - 315 nm |
1024 |
0.24 - 0.29 nm |
7-177 @ 50 % albedo and 60° Solar Zenith Angle |
311 - 403 nm |
1024 |
0.26 - 0.28 nm |
372-3000 @ 50 % albedo and 60° SZA |
401 - 600 nm |
1024 |
0.44 - 0.53 nm |
4000 @ 50 % albedo and 60° SZA |
590 - 790 nm |
1024 |
0.44 - 0.53 nm |
2000-4000 @ 50 % albedo and 60° SZA |
312 - 790 nm |
200 |
2.8 nm at 312 nm to 40 nm at 790 nm |
100 for λ< 400 nm, 1000 for 400 nm < λ < 790 nm |