Global Ozone Monitoring by Occultation of Stars (GOMOS)
GOMOS |
Global Ozone Monitoring by Occultation of Stars |
Satellite |
Envisat |
Status |
Operational – Utilised in the period 2002 to ~ 2013 |
Mission |
Profiles of ozone and other species. Tracked species: O3, H2O, NO2, NO3, OClO, BrO, ClO and aerosol |
Instrument type |
UV/VIS/NIR grating spectrometer, three bands, ~ 1000 channels, two broadband channels for scintillations |
Scanning technique |
Limb sounding during occultation of 25-40 stars/orbit, i.e. average 500 occultations/day |
Coverage/cycle |
One global coverage/day with one measurement every 1000 x 1000 km2 cell in average |
Resolution |
Vertical: 1.7 km, in the altitude range 20-100 km. Horizontal effective resolution: ~ 300 km (limb geometry) |
Resources |
Mass: 163 kg - Power: 146 W - Data rate: 222 kbps |
Spectral range |
Number of channels |
Spectral resolution |
SNR at specified input radiance |
248 - 693 nm |
~ 500 |
0.89 nm |
12 @ …............ |
750 - 776 nm |
~ 200 |
0.12 nm |
6 @ ….......... |
915 - 956 nm |
~ 300 |
0.12 nm |
3 @ ….......... |
466 - 705 nm |
2 |
466-582 nm, 644-705 nm |
15 @ …….…… |