Multiple Channel Scanning Imager (MCSI)
MCSI |
Multiple Channel Scanning Imager |
Satellites |
FY-4 O A/B and follow-on |
Status |
Being defined - To be utilised from 2012 onward |
Mission |
Multi-purpose VIS/IR imagery and wind derivation by tracking clouds and water vapour features |
Instrument type |
12-channel VIS/IR radiometer |
Coverage/cycle |
Full disk every 30 min. Limited areas in correspondingly shorter time intervals |
Resolution (s.s.p.) |
From 1 to 4 km (see table) |
Resources |
Mass: … kg - Power: … W - Data rate: … Mbps |
Central wavelength |
Spectral interval |
Radiometric accuracy (NEΔT or SNR) |
Resolution @ s.s.p. |
0.65 µm |
0.55 - 0.75 µm |
200 @ 100 % albedo |
1 km |
0.825 µm |
0.75 - 0.90 µm |
200 @ 100 % albedo |
1 km |
1.375 µm |
1.36 - 1.39 µm |
200 @ 100 % albedo |
2 km |
1.61 µm |
1.58 - 1.64 µm |
200 @ 100 % albedo |
2 km |
2.25 µm |
2.1 - 2.35 µm |
200 @ 100 % albedo |
2 km |
3.75 µm |
3.5 - 4.0 µm |
0.3 K @ 300 K |
4 km |
6.25 µm |
5.8 - 6.7 µm |
0.3 K @ 260 K |
4 km |
7.1 µm |
6.9 - 7.3 µm |
0.3 K @ 260 K |
4 km |
8.5 µm |
8.0 - 9.0 µm |
0.2 K @ 300 K |
4 km |
10.7 µm |
10.3 - 11.1 µm |
0.2 K @ 300 K |
4 km |
11.0 µm |
11.5 - 12.5 µm |
0.2 K @ 300 K |
4 km |
13.5 µm |
13.2 - 13.8 µm |
0.5 K @ 300 K |
4 km |