Medium Resolution Spectral Imager (MERSI)

MERSI

Medium Resolution Spectral Imager

Satellites

FY-3 A to G

Status

Operational – Utilised in the period: 2008 to ~ 2024

Mission

Vegetation indexes and ocean colour

Instrument type

20-channel radiometer, 19 narrow-bandwidth in VIR/NIR/SWIR and one broadband in the Thermal IR

Scanning technique

Cross-track: 2048 (8192) pixels of 1 km (250 m) ssp, swath 2900 km - Along-track: ten 10-km lines every 1.5 s

Coverage/cycle

Global coverage in 1 day (in daylight)

Resolution (s.s.p.)

250 m for broad-band channels, 1.0 km for narrow-band channels

Resources

Mass: … kg - Power: … W - Data rate: … Mbps



Channel set

Central wavelength

Spectral range or Bandwidth

Radiometric accuracy (NEΔT or NEΔρ)

Broad-band channels with 250 m resolution, mostly for clouds, vegetation and surface temperature

0.470 µm

0.445 - 0.495 µm

0.45 %

0.550 µm

0.525 - 0.575 µm

0.4 %

0.650 µm

0.625 - 0.675 µm

0.3 %

0.865 µm

0.840 - 0.890 µm

0.3 %

11.250 µm

10.0 - 12.5 µm

0.3 K @ 300 K

Narrow-band channels with 1000 m resolution, for ocean colour, vegetation, aerosol

412 nm

20 nm

0.1 %

443 nm

20 nm

0.1 %

490 nm

20 nm

0.05 %

520 nm

20 nm

0.05 %

565 nm

20 nm

0.05 %

650 nm

20 nm

0.05 %

685 nm

20 nm

0.05 %

765 nm

20 nm

0.05 %

865 nm

20 nm

0.05 %

905 nm

20 nm

0.10 %

940 nm

20 nm

0.10 %

980 nm

20 nm

0.10 %

1030 nm

20 nm

0.10 %

1640 nm

50 nm

0.05 %

2130 nm

50 nm

0.05 %



Last updated June 2008