Multi-Spectral Imager (MSI) for Sentinel-2
MSI |
Multi-Spectral Imager |
Satellites |
Sentinel-2 A and B |
Status |
Being developed – To be utilised in the period 2012 to ~ 2021 |
Mission |
Land observation, vegetation, territory management and hazards mitigation |
Instrument type |
12-channel VIS/NIR/SWIR spectro-radiometer |
Scanning technique |
Pushbroom, swath ≥ 200 km nominally close to nadir, pointable off-track for emergencies |
Coverage/cycle |
Global coverage in 2 weeks, in daylight. More frequent possible for emergencies |
Resolution (s.s.p.) |
IFOV: 10 to 60 m. depending on channel (see table) |
Resources |
Mass: … kg - Power: … W - Data rate: … Mbps |
Central wavelength |
Bandwidth |
Radiometric accuracy (SNR @ specified input radiance) |
IFOV at s.s.p. |
443 nm |
20 nm |
129 @ 129.11 W m-2 sr-1 µm-1 |
60 m |
490 nm |
65 nm |
154 @ 128.00 W m-2 sr-1 µm-1 |
10 m |
560 nm |
35 nm |
168.4 @ 128.00 W m-2 sr-1 µm-1 |
10 m |
665 nm |
30 nm |
142.1 @ 108.00 W m-2 sr-1 µm-1 |
10 m |
705 nm |
15 nm |
117 @ 74.60 W m-2 sr-1 µm-1 |
20 m |
740 nm |
15 nm |
89 @ 68.23 W m-2 sr-1 µm-1 |
20 m |
775 nm |
20 nm |
105 @ 66.70 W m-2 sr-1 µm-1 |
20 m |
842 nm |
115 nm |
174.6 @ 103.00 W m-2 sr-1 µm-1 |
10 m |
865 nm |
20 nm |
72 @ 52.39 W m-2 sr-1 µm-1 |
20 m |
940 nm |
20 nm |
114 @ 8.77 W m-2 sr-1 µm-1 |
60 m |
1375 nm |
20 nm |
50 @ 6.00 W m-2 sr-1 µm-1 |
60 m |
1610 nm |
90 nm |
100 @ 4.00 W m-2 sr-1 µm-1 |
20 m |
2190 nm |
180 nm |
100 @ 1.70 W m-2 sr-1 µm-1 |
20 m |